Seccional Girardot Office 365 Egresados

Institutional Repository
Universidad Piloto de Colombia

    • Login
    JavaScript is disabled for your browser. Some features of this site may not work without it.
    View Item 
    •   Universidad Piloto de Colombia
    • Trabajos de grado - Pregrado
    • Facultad de Ingenierías
    • Ingeniería Civil
    • View Item
    •   Universidad Piloto de Colombia
    • Trabajos de grado - Pregrado
    • Facultad de Ingenierías
    • Ingeniería Civil
    • View Item

    Obtención de carbón activado a partir de cáscara de mangostino para ser utilizado en la retención de AL3+ en aguas potables

    Thumbnail
    View/Open
    Trabajo de Grado (2.499Mb)
    Date
    2020-05-04
    Author
    Rodriguez Rodriguez, Diana Lorena
    Leiton Ducuara, Jhon Alexander
    Velez Bohorquez, Isabel
    xmlui.dri2xhtml.METS-1.0.item-advisor
    Fonseca Correa, Rafael Alberto / Director
    Húmpola, Pablo Danilo / Codirector
    QR Code
    xmlui.mirage2.itemSummaryView.ShareSection
    Exportar a Mendeley
    Metadata
    Show full item record
    Abstract
    En la actualidad para el proceso de potabilización de agua, se somete el líquido a diferentes sistemas de tratamiento con el fin de retener los contaminantes que puedan afectar la salud de quien la consume. La resolución 2115 de 2007 establece los máximos aceptables en cada uno de los parámetros fisicoquímicos que deben ser analizados por las plantas de tratamiento de agua potable. En la ciudad de Bogotá, en el barrio san Luis se encuentra ubicado una planta de tratamiento de agua potable “Acualcos”, un acueducto veredal que ha sido construido por la comunidad debido a la falta del suministro de agua potable para la población, se ha evidenciado que en algunas ocasiones el agua presenta valores de Aluminio (Al3+) por encima del valor estipulado por la norma debido al proceso de coagulación al que es sometida el agua. Debido a esto, se determinó realizar el estudio de carbón activado a partir de cascara de mangostino para la retención de Al3+; este material orgánico genera grandes beneficios para la retención de Aluminio, debido a que aproximadamente el 70% del fruto es cascara y posee características como dureza y resistencia. Se realizo la activación de tres carbones con diferentes tipos de agentes químicos, entre los que están: carbón de carácter físico activado con CO2, carbón de carácter acido activado con ácido fosfórico (H3PO4) y carbón de carácter alcalino activado con hidróxido de sodio (NaOH) ; una vez fabricados, se sometieron a diferentes pruebas de muestra de agua de la PTAP Acualcos con el fin de estudiar cuál de ellos presenta un mejor comportamiento respecto a la retención de contaminantes, especialmente en Al3+.
     
    Currently for the water purification process, the liquid is subjected to different treatment systems in order to retain contaminants that may affect the health of the person who consumes it. Resolution 2115 of 2007 sets the maximum acceptable values in each of the physicochemical parameters to be analysed by drinking water treatment plants. In Bogotá city, San Luis neighborhood is located a drinking water treatment plant "Acualcos", a veredal aqueduct that has been built by the community due to the lack of drinking water supply for the population, it has been shown that in sometimes water has Aluminium (Al3+) values above the value stipulated by the standard due to the coagulation process to which the water is subjected. Because of this, it was determined to conduct the study of activated carbon from mangostine shell for the retention of Al3+; this organic material generates great benefits for the retention of Aluminum, because approximately 70% of the fruit is shell and has characteristics such as hardness and strength. The activation of three carbons was done with different types of chemical agents, among which are: carbon of a physical character activated with CO2, acid carbon activated with phosphoric acid (H3PO4) and alkaline carbon activated with sodium hydroxide ( NaOH) ; once manufactured, they underwent different water sample tests of the PTAP Acualcos in order to study which of them has the best behavior regarding the retention of contaminants, specially in AL3+.
     
    URI
    http://repository.unipiloto.edu.co/handle/20.500.12277/7597
    Collections
    • Ingeniería Civil [426]

    DSpace software copyright © 2002-2016  DuraSpace - Cristhian Rey
    Contact Us | Send Feedback
    Theme by 
    Atmire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2016  DuraSpace - Cristhian Rey
    Contact Us | Send Feedback
    Theme by 
    Atmire NV
     

     

    BIBLIOTECA UNIPILOTO
    Reglamento
    Reglamento
    Buzón de Sugerencias
    Buzón
    UBICACIÓN
    www.unipiloto.edu.co
    Universidad Piloto de Colombia
    Sede Bogotá
    Carrera 9 No. 45A - 44
    Para mayor información comuniquese al conmutador: (1) 332 29 00
    Línea gratuita nacional: 01 8000 110452
    PBX de Posgrados: 232 4122
    Universidad Piloto de Colombia
    Seccional Alto Magdalena - Girardot
    Carrera 19 No. 17 - 33
    Conmutador Girardot: (1) 836 0600
    Admisiones Girardot: 320 454 4348
    Universidad Piloto de Colombia
    Todos los derechos reservados © 2014
    • Inicio
    • Aspirantes
    • Estudiantes
    • Docentes
    • Egresados
    • Convocatorias
    • Valores de Matrícula 2018
    • Política de tratamiento de la información
    • Aviso de privacidad
    • Solicitudes