En la presente investigación se realiza el estudio y diagnóstico de las condiciones actuales de
la planta de tratamiento del municipio de San Juan de Rioseco, administrado por la oficina
de servicios públicos domiciliarios, acueducto, alcantarillado y aseo de San Juan de Rioseco,
Cundinamarca y de la calidad del agua potable generada por esta, en la cual no se abordarán
criterios de operaciones unitarias del proceso si no de las condiciones de las operaciones.
Esta es una investigación con un alto enfoque social en donde se formulan propuestas de
mejoramiento de acuerdo a los resultados obtenidos.
Se abordan las consecuencias económicas, sociales y ambientales que ha generado la calidad
del agua en los habitantes, planteando una serie de alternativas y recomendaciones para la
mejora del servicio y formulando un dictamen de acuerdo a los resultados sobre el estado
actual de la planta de tratamiento de agua potable (PTAP), Se ha verificado si se ha mejorado
la calidad del agua que es distribuida a los usuarios del sistema de acueducto en comparación
de años anteriores.
Los resultados del IRCA del año 2015 y 2016 indican que la calidad del agua se encuentra
en riesgo medio y en algunos meses ha llegado a alcanzar el nivel de riesgo alto, el
inconformismo de la comunidad y la inseguridad que genera consumir agua en condiciones
inapropiadas, ha generado un riesgo de salud pública para los habitantes de dicha población
y ha sido fuente de inspiración para llevar a cabo este trabajo de investigación.
Se Identificaron las características propias de la comunidad y demás involucrados en el
proceso del tratamiento de aguas potables, se acudieron a técnicas de recolección de
información, como lo son entrevistas a funcionarios encargados del control y supervisión de
la PTAP por medio de la alcaldía municipal de San Juan de Rioseco y la secretaría de
servicios públicos, entrevistas a la comunidad del casco urbano, visitas de campo a las
instalaciones de la PTAP identificando y reconociendo cada una de las estructuras que
componen la PTAP, se realizó recolección de muestras de agua para la respectiva valoración
y realización de pruebas de laboratorio con el fin de realizar la caracterización física y
química del agua, los ensayos y las pruebas de laboratorio se realizaron en los laboratorios
de la universidad Piloto de Colombia.
Como resultado de este trabajo de investigación, se realizó la calificación IRCA (parcial), se
obtuvo que la calidad del agua potable que es distribuida a los habitantes del casco urbano
de San Juan de Rioseco, en la actualidad de la evaluación, se encuentra en óptimas
condiciones y es apta para el consumo humano cumpliendo con algunos de los lineamientos
más importantes establecidos por la resolución 2115 de 2015. Sus fuentes de abastecimiento
son aguas de muy buena calidad y cantidad, que cumplieron en casi todos los parámetros
evaluados.
De acuerdo con la evaluación y descripción realizada en cada una de las estructuras que
componen la PTAP se determinaron aspectos de mejora. Los riesgos en la calidad del agua
disminuyeron gracias al mejoramiento que esta ha recibido en los últimos años, el
funcionamiento de la planta se encuentra en condiciones adecuadas con aspectos por mejorar,
14
la calidad del agua mejoro significativamente, la percepción de los usuarios y el sentido de
pertenencia hacia el sistema de acueducto también ha mejorado y las consecuencias
económicas, sociales y ambientales que genera el agua en mal estado a los habitantes del
municipio también se han visto en mejora, trayendo así beneficios y mejorando la calidad de
vida de los sanjuaneros.
Se encontraron ciertas fallas y falencias durante el proceso de la investigación, es cierto que
se ha mejorado bastante la infraestructura y el manejo de la PTAP y el objetivo de la
administración municipal 2020-2023 es ampliar y mejorar la cobertura del sistema de
acueducto y alcantarillado, con la instalación de nuevos macromedidores y micromedidores,
la reparación de tramos en mal estado de tubería de alimentación y distribución con el fin de
disminuir las perdidas, pero aún falta mejorar algunos aspectos para prestar un excelente
servicio, se encontró una escaza y precaria capacitación a los operarios de la PTAP. In this research, the study and diagnosis of the current conditions of the treatment plant of
the municipality of San Juan de Rioseco, administered by the office of home public services,
aqueduct, sewerage and cleaning of San Juan de Rioseco, Cundinamarca and of the quality
of the drinking water generated by it. This is a research with a high social focus where
improvement proposals are formulated according to the results obtained.
The economic, social and environmental consequences that the water quality has generated
in the inhabitants are addressed, proposing a series of alternatives and recommendations for
the improvement of the service and formulating an opinion according to the results on the
current state of the treatment plant drinking water supply (PTAP). It has been verified
whether the quality of the water that is distributed to the users of the aqueduct system has
improved compared to previous years.
The IRCA results for 2015 and 2016 indicate that the quality of the water is at medium risk
and in some months, it has reached a high-risk level, the community's nonconformity and the
insecurity generated by consuming water in inappropriate conditions. It has generated a
public health risk for the inhabitants of this population and has been a source of inspiration
to carry out this research work.
The research process was based on carrying out a study, diagnosis and description of the
current state of the structures that make up the drinking water treatment plant (PTAP),
carrying out a rigorous evaluation of the physical state, operation and efficiency of these and
of the current state of the quality of the water for human consumption, carrying out
physicochemical tests on the water coming from its supply sources at the entrance of the
PTAP and at the exit of this to the already treated and purified water that will be distributed
to the final consumer. Recommendations were formulated for improvement through the
characterization of technical and health risk aspects, established in resolution 2115 of 2007.
The characteristics of the community and others involved in the drinking water treatment
process were identified, information gathering techniques were used, such as interviews with
officials in charge of control and supervision of the PTAP through the municipal mayor's
office of San Juan de Rioseco and the secretary of public services, interviews with the
community of the urban area, field visits to the facilities of the PTAP identifying and
recognizing each one of the structures that make up the PTAP, collection of water samples
for the respective assessment and performance of laboratory tests in order to carry out the
physical and chemical characterization of the water, the tests and laboratory tests were carried
out in the laboratories of the Pilot University of Colombia.
As a result of this research work, the IRCA qualification (partial) was carried out, it was
obtained that the quality of the drinking water that is distributed to the inhabitants of the
urban area of San Juan de Rioseco, at the present time of the evaluation, is in optimal
16
conditions and is suitable for human consumption, complying with some of the most
important guidelines established by resolution 2115 of 2015. Its sources of supply are water
of very good quality and quantity, which met almost all the parameters evaluated. One of the
aspects and problems that arose during the execution of this research work was the restriction
imposed by the national government due to the pandemic caused by the COVID-19 virus,
therefore, it was not possible to evaluate all the characteristics mentioned. in resolution 2115
of 2007, since the Pilot University of Colombia does not have the equipment to carry out the
microbiological tests, to carry out the complete calculation of the IRCA and thus achieve a
better characterization of it.
In accordance with the evaluation and description made in each of the structures that make
up the PTAP, aspects of improvement were determined. The risks in water quality decreased
thanks to the improvement that it has received in recent years, the operation of the plant is in
adequate conditions with aspects to improve, the quality of the water improved significantly,
the perception of the users and the sense Belonging to the aqueduct system has also improved
and the economic, social and environmental consequences that water in poor condition
generates for the inhabitants of the municipality have also improved, thus bringing benefits
and improving the quality of life of San Juan residents.
Certain flaws and shortcomings were found during the investigation process, it is true that
the infrastructure and management of the PTAP has been greatly improved and the objective
of the municipal administration 2020-2023 is to expand and improve the coverage of the
aqueduct and sewerage system , with the installation of new macrometers and micrometers,
the repair of sections in poor condition of the supply and distribution pipeline in order to
reduce losses, but some things still need to be improved to provide excellent service, there
was a shortage and precarious training to the operators of the PTAP and it is recommended
to use a dosage of 80 mg / L of aluminum sulfate for each liter of water treated in the PTAP.
Collections